Field Description
Select the file to be copied.
Configuration contains
certificates/keys
Only for Command Type = )
= and Action = 6%  or :#
% 
Select whether the certificates and keys contained in the config-
uration are to be imported or exported.
The function is disabled by default.
Encrypt configuration
Only for Command Type = )
= and Action = 6%  or :#
% 
Define whether the data of the selected Action are to be en-
crypted..
The function is disabled by default.
Reboot after execution
Only if Command Type = ) =
Select whether your device should restart after the intended Ac-
tion.
The function is disabled by default.
Version Check
Only for Command Type = )
= and Action = 6% 
Select whether, when importing a configuration file, to check on
the server for the presence of a more current version of the
already loaded configuration. If not, the file import is interrupted.
The function is disabled by default.
Destination IP Address
Only if Command Type = ! /
Enter the IP address whose accessibility is to be checked.
Source IP Address
Only if Command Type = ! /
Enter an IP address to be used as sender address for the ping
test.